Pantalla GLCD 128x128
Modelo Nº WG128128A
►LCD Grafico 128x128 puntos
►Controlador integrado RA6963
►1/128 duty cycle
►Voltaje negativo opcional
►Fuente de alimentación de 5V
►Interfaz : 8080
DIBUJO

ESPECIFICACIONES
Función interfaz Pin
| Pin No. | Símbolo | Función |
|---|---|---|
| 1 | FGND | Frame ground |
| 2 | GND | Ground |
| 3 | VDD | Power supply for logic |
| 4 | VO | Contrast Adjustment |
| 5 | /WR | Data write. Write data into LCD Controller |
| 6 | /RD | Data read. Read data from LCD Controller |
| 7 | /CE | Enable signal |
| 8 | C/D | Data/ Instruction select signal |
| 9 | NC | No connection |
| 10 | /RESET | Controller reset signal, Active Low |
| 11~18 | DB0~DB7 | Data bus line |
| 19 | FS | Selection of font; H : 6 * 8 , L : 8 * 8 |
| 20 | VEE | Negative Voltage Output |
| 21 | A | Power supply for B/L + |
| 22 | K | Power supply for B/L - |
Datos mecánicos
| Elemento | Valor estándar | Unidad |
|---|---|---|
| Dimensión del módulo | 85.0 × 100.0 | mm |
| Área de visualización | 62.0 × 62.0 | mm |
| Orificio de montaje | 75.0 × 94.0 | mm |
| Distancia entre puntos | 0.43 × 0.43 | mm |
| Tamaño del punto | 0.40 × 0.40 | mm |
Características electrónicas
| Elemento | Símbolo | Valor estándar Valor típico |
Unidad |
|---|---|---|---|
| Input Voltage | VDD | 3/5 | V |
| Tensión de conducción LCD recomendada para temp. normal Módulo versión @25°C | VDD-VO | 16.35 | V |